The servers are yours, the data center is ours. Bring your hardware to our facility in Trabzon and run it under redundant power, precision cooling, carrier-neutral connectivity and 7-layer security. From a single server to a private cage, rent as much space and power as you need.
Power, cooling, security and NOC monitoring are standard in every plan. Choose the plan and set the power and connectivity in the configurator according to your needs.
Choose the space, the power per cabinet, the power feed and the connectivity; our sales team will prepare a quote specific to your configuration.
Space type
Power per cabinet
Power options that do not fit your chosen space type are disabled. Densities above 10 kW are offered in high-density rows.
For 1U–4U hosting, 0.5 kW of power per server is included in the plan; no separate power selection is needed.
Power feed
Recommended for dual-power-supply servers; maintenance or failure of one feed does not cause an outage.
Contract term
Your preferred contract term is taken into account in your quote.
Internet connectivity
IP transit: committed bandwidth, BGP multi-homed backbone and DDoS protection included. With your own carrier, the bandwidth indicates the port speed; the line fee is paid to your carrier.
IPv4 block
The IPv6 /48 block is free with all space types.
Fiber / copper connections to carriers or other customers. At least 1 is required with your own carrier.
Additional services
INCLUDED IN EVERY CABINET
You focus on your hardware, we handle the rest
A single 1U server and a four-cabinet cage are fed by the same redundant infrastructure and monitored by the same NOC team.
Smart PDU & kW metering
PDUs fed from the A and B feeds that measure per outlet. You monitor your consumption live from the portal.
2N UPS · N+1 generator
In a mains outage the UPS takes over, and the generators power the facility without interruption on 72 hours of fuel.
Precision cooling
Inlet temperature within the ASHRAE recommended range from N+1 CRAH units with cold aisle containment.
7-layer security
From perimeter security to biometric entry and the mantrap; only the people you authorize can reach your cabinet.
Carrier-neutral connectivity
Use NuageDC IP transit, or bring your own carrier to your cabinet through the Meet-Me-Room.
24/7 NOC monitoring
Power, temperature and humidity thresholds are monitored continuously; on an anomaly the NOC team acts before you do.
Remote hands
Reboots, visual checks and cabling work; 2 hours per month are included in the full cabinet plan.
Customer portal
Power and temperature graphs, access logs, visit notifications and support requests on a single screen.
For all the technical details of the infrastructure, see the Trabzon Data Center page.
REMOTE HANDS & ADDITIONAL SERVICES
No need to come to Trabzon
Our on-site technical team performs physical work in your cabinet on request and reports each task with photos and notes.
Remote hands tasks, scope and target times
Task
Scope
Target time
Report
Restart / power cycle
Included · unlimited
15 min
Instant notification
Visual check, LED and display information
Included · unlimited
15 min
With photos
Cable connecting, replacing, labeling
From the monthly hours pack
30 min
With photos
Disk, memory, part replacement
From the monthly hours pack
1 hour
With serial number record
KVM / console connection, OS installation support
Charged hourly
1 hour
Task note
Rack & stack, cabling
Charged per device
By appointment
Cabinet layout plan
Hardware receiving & storage
Included for up to 7 days
Business hours
Delivery receipt
Migration support
Project-based
Scheduled
Migration plan
Target times are measured from the moment the request reaches the NOC until work begins. The monthly hours pack can be increased in the configurator.
CONNECTIVITY OPTIONS
You choose your carrier
Our facility is carrier-neutral. You can get internet access from us, bring your own line, or use both together to build a redundant setup.
IP transit
BGP multi-homed internet access over our 4×100G backbone; L3/L4 DDoS protection included, commitments from 100 Mbps to 10 Gbps.
Cross-connect
Direct fiber or copper connections through the Meet-Me-Room to carriers in the facility or to other NuageDC customers.
BGP with your own ASN
Announce your own IP blocks and ASN with a BGP session; full routing table or default route options.
Private lines
Private connections to your offices and other locations over metro ethernet or MPLS that do not go out to the internet.
Need backbone, DDoS and peering details? Explore all our connectivity services and our network architecture in detail.
We move a single server in a few days, and multiple cabinets on a planned schedule. At every step you work with a single technical contact.
STEP 1
Site survey & capacity plan
Your hardware list, power consumption and connectivity needs are worked out; the right space and kW are determined. If you wish, tour the facility on site.
STEP 2
Contract & access list
The cabinet is allocated and IP blocks are reserved; the people who will access the facility are defined, and their cards and biometric enrollments are prepared.
STEP 3
Hardware receiving
Devices delivered by cargo or by hand are logged with their serial numbers and kept in a secure area until installation day.
STEP 4
Rack & stack, cabling
Devices are mounted according to the layout plan, and the A+B power and network cables are labeled and connected neatly.
STEP 5
Go-live
Connectivity and power tests are completed and NOC monitoring begins; your portal access and cabinet layout report are delivered.
Migration support. When you move from your existing server room or another data center, we are with you for decommissioning, insured transport coordination and outage window planning.
For those who want to host their own hardware with confidence
Organizations of every size that want to be rid of the burden of running a server room, keep their data in Türkiye, or set up a connection point in the region.
Corporate IT
Move the power, cooling and security risks of the office server room to a corporate facility; your hardware and licenses stay yours.
Finance & public sector
An isolated cabinet or cage with logged access, for regulations that require data to stay in Türkiye and on the institution's own hardware.
ISP & carrier PoP
Set up a point of presence (PoP) in the Eastern Black Sea; connect directly to other carriers and enterprise customers through cross-connects.
SaaS & software
A production environment that scales at predictable cost on hardware you optimize yourself; hybrid with Cloud when needed.
Broadcast & media
10 Gbps connectivity for broadcast, encoding and content delivery servers that need high bandwidth and low latency.
Disaster recovery site
A DR site geographically separate from your main server room; set up replication with your own hardware or with DRaaS.
FREQUENTLY ASKED QUESTIONS
Common questions
We have answered the most frequently asked questions about our colocation service. Contact our team to work out your capacity plan together.
You can access our facility 24 hours a day, 7 days a week. For security, visits are notified in advance through the customer portal or the NOC; one day's notice is enough for planned visits, and short notice is enough in emergencies. During a visit you access only your own cabinet or cage area.
Access authorization is granted only to the people on the access list defined in the contract, and you manage the list from the portal. ID is checked at entry; with card access, biometric verification and the mantrap, you reach only your own area. Visitors not on the list are admitted accompanied by an authorized person from your side or by our staff. All passages are logged.
Each cabinet is metered by a smart PDU and you monitor your consumption live from the portal. When consumption approaches the 80% threshold of the committed power, the NOC informs you. Short-lived peaks are not a problem; if a permanent increase is needed, your cabinet power is raised to the next level with cooling capacity planned accordingly. With an A+B feed, the load on each feed is planned so that the other can carry it if one feed goes out of service.
You can start with a monthly contract. A 12-month contract provides a 5% discount on monthly fees and a 50% advantage on setup; a 36-month contract provides a 12% discount and free setup. During the contract you can grow your space and power.
You can ship your hardware by cargo or bring it yourself. Our facility accepts deliveries during business hours, logs them with serial numbers, and stores them in a secure area free for up to 7 days until installation day. You can do the mounting and cabling yourself or leave it to our remote hands team.
The facility, the building and the infrastructure systems are covered by NuageDC's insurance. For the hardware itself, we recommend taking out your own equipment insurance; we provide the facility security, fire suppression and access control information and documents that your insurer requests.
In the customer portal you can monitor cabinet power consumption, inlet temperature, humidity and access logs, and define threshold alarms. As an additional service, you can view your cabinet with an in-cabinet camera and receive door-opening notifications.
No. With our IP transit service we provide IPv4 blocks from /29 to /24 and a free IPv6 /48. If you have your own IP blocks and ASN, you can announce them with a BGP session, or bring your own carrier's line directly to your cabinet with a cross-connect.
GET A QUOTE
Let's talk about your project and prepare a quote tailored to you.
Briefly share your needs; our solution architects will review your current infrastructure and get back to you with a recommendation that balances performance, security and budget.
Reply within 2 business hoursDuring business hours your request is evaluated quickly.
Direct technical expertYou talk to a solution architect, not a sales rep.
Free migration planMigration steps are clarified together with the quote.