DATA CENTER

Trabzon Data Center

The uninterrupted digital backbone of the Black Sea region. Every layer, from power and cooling to fire detection and physical security, is designed with a redundant architecture and operated by an on-site 24/7 NOC team; it is the one and only data center of our own where all NuageDC services run. Your data stays in Türkiye, KVKK compliant and secure.

TRABZON-DC1

40.99° N · 39.77° E · Trabzon Teknokent

All systems operational
  • Power2N · A+B activeOK
  • CoolingN+1 · 23,1 °COK
  • FireVESDA · normalOK
  • Security7 layers · activeOK
  • Network4×100G · BGP 6/6OK
PUE (live)
1,36
IT load
%64
NOC
7/24
  • Tier IIIdesign principles
  • 2N UPSA+B independent feeds
  • 4×100Gbackbone connectivity
  • 24/7 NOCon-site expert team
  • PUE 1.37annual efficiency target

WHY TRABZON?

The Black Sea's data center, the guarantee of your business continuity

Location is the least changeable property of a data center. With its climate, geographic position and connectivity to the main business hubs, Trabzon offers a strong foundation for long-term, secure infrastructure.

  • A climate suited to free cooling

    The mild climate of the Black Sea makes outside-air cooling (free-cooling) possible for most of the year; lower energy consumption and a better PUE.

  • Geographic risk diversification

    A location geographically separated from the busy business hubs gives disaster recovery scenarios a facility that does not share the same regional risk as your head office; the site was also selected with seismic hazard in mind.

  • Low latency to business hubs

    With a multi-carrier backbone connection, you reach your users in Istanbul, Ankara and Bursa within milliseconds.

  • Domestic data, KVKK compliance

    All our services run in this facility; your data stays in Türkiye. It is also a nearby local infrastructure for public institutions, universities and industry in the region.

Location & access

40.99° N · 39.77° E
Map of Türkiye: the NuageDC data center is in Trabzon; low-latency access to Istanbul, Ankara and Bursa TrabzonData Center Istanbul Ankara Bursa
Data center (Trabzon) Low-latency access
→ Istanbul
~12 ms
→ Ankara
~9 ms
→ Bursa
~14 ms

Typical round-trip (RTT) values; they may vary by route and carrier.

FACILITY FLOOR PLAN

Explore the facility layer by layer.

Click a system on the floor plan or the tabs below; see the role and key technical values of every area, from the power room to the Meet-Me-Room, in the panel on the right.

Floor Plan // DC1 · Floor 0
TRABZON-DC1 · BUILDING SHELL HALL B · EXPANSION AREA LOGISTICS CRAHCRAHCRAHCRAH COLD AISLE COLD AISLE HOT AISLE 02 ABCD 07 GEN-1GEN-2GEN-3 GENERATOR YARD UPS AUPS B POWER ROOM · 2N 01 NOVEC 1230 · GAS ROOM VESDA ▸ 03 ENTRANCE · MANTRAP 04 FIBER AFIBER B MMR · NETWORK 05 NOC · 24/7 06
Spec ReadoutSYS-01

Power Infrastructure

Dual medium-voltage feeds, 2N modular UPS and N+1 generators deliver uninterrupted power with no single point of failure.

UPS topology
2N (A+B)
Go to System Details

INFRASTRUCTURE SYSTEMS

No single point of failure: every system is redundant

A data center's reliability is only as strong as its weakest link. Below you will find the nine critical systems of our facility: how they work, the redundancy level they are designed with, and their key technical values.

01 — POWER DISTRIBUTION

Redundancy · 2N

Two independent paths, zero single points of failure

The facility is fed by two separate medium-voltage lines coming from different substations. Each line runs, physically separate, all the way to the rack with its own transformer, switchboard group, UPS system and PDU; even if one of the A and B paths is under maintenance or has failed, your racks continue to be powered at full capacity from the other path.

Automatic transfer (ATS) and static transfer (STS) switches change over between sources within milliseconds. All switchboards are metered; energy consumption is monitored and reported per rack.

Grid
2 × MV lines · separate transformers
Topology
2N (A+B) distribution
Transfer
ATS / STS < 10 ms
IT capacity
1.2 MW (Phase 1)
Rack feed
A+B smart PDU
Monitoring
Per switchboard & rack
POWER PATH · SINGLE-LINE DIAGRAMSCROLL →
GRID ATRANSFORMER AATS / STSUPS APDU A GRID BTRANSFORMER BATS / STSUPS BPDU B GEN · N+1 RACK PATH APATH B

The A and B paths are physically separate; the failure or maintenance of a single component does not interrupt the power to the rack.

02 — UNINTERRUPTIBLE POWER SUPPLY

Redundancy · 2N

The moment the grid fails, zero interruption

Each power path has its own modular double-conversion (online) UPS system. Grid fluctuations, voltage sags and outages are absorbed by the UPS before they reach your servers; until the generators come online, the entire load is fed from the batteries.

Thanks to the modular structure, power modules can be replaced while the system is running. Battery blocks are monitored continuously at cell level; internal resistance and temperature trends let us plan maintenance before a failure occurs.

Topology
2N · A and B separate
Type
Modular · online
Autonomy
≥ 10 min (full load)
Maintenance
Hot-swap modules
Battery monitoring
Cell level · 24/7

TRANSFER TIME

0 ms

Online topology, no interruption on transfer

BATTERY AUTONOMY

≥ 10 min

Far beyond generator start-up time

EFFICIENCY

%96+

High-efficiency modular UPS

03 — GENERATOR

Redundancy · N+1

72 hours of autonomy against long outages

The diesel generators in the generator yard are N+1 redundant: one unit beyond the capacity needed to carry the facility's full load is always on standby. When a grid outage is detected, the generators start automatically, synchronize, and take over the load through the transfer switchboards.

The on-site fuel tanks are enough to run for at least 72 hours at full load. Priority supply agreements with regional fuel suppliers secure refueling during long outages.

Redundancy
N+1 diesel generator
Start-up
< 15 s
Fuel autonomy
≥ 72 h · full load
Refueling
Priority supply agreement
Testing
Monthly on load · annual load bank

AT THE MOMENT OF A GRID OUTAGE · TIMELINE

  1. T + 0 ms

    UPS takes over

    The load is fed from the batteries without interruption.

  2. T + 3 s

    Generators start

    The outage is confirmed and all units start automatically.

  3. T + 15 s

    Load transfer

    Synchronized generators take over the load via the ATS.

  4. T + 72 h

    Full autonomy

    Runtime at full load without refueling.

04 — COOLING

Redundancy · N+1

Constant temperature, contained aisles, a climate advantage

In the white space, rack rows are placed facing each other and cold aisles are physically contained. Cold air reaches only the front of the servers, and hot exhaust air is taken into the return path without mixing; as a result, every rack sees the same intake temperature regardless of its position.

N+1 redundant precision-controlled CRAH units are supported by in-row units in high-density rows. The mild climate of the Black Sea reduces compressor load through free cooling (free-cooling) for most of the year.

Units
CRAH + in-row · N+1
Architecture
Cold aisle containment
Intake temperature
22–24 °C
Humidity
40–60% RH
Standard
ASHRAE A1 range
Free cooling
~60% of the year
AIRFLOW · CROSS-SECTIONSCROLL →
HOT AIR RETURN · CEILING PLENUM CRAHN+1 RAISED FLOOR · COLD AIR COLD AISLE22–24 °C HOT AISLE HOT AISLE RACKRACK

05 — FIRE DETECTION & SUPPRESSION

Zoned · NOC integrated

Detects before smoke is visible, suppresses without touching equipment

The VESDA aspirating early detection system continuously samples hall air through a pipe network and detects microscopic particles at the earliest stage of combustion, before smoke is visible to the eye. Alarm levels are staged; at the first warning, the NOC team responds on site.

For suppression, a Novec 1230 gas system is used instead of water: it is non-conductive, leaves no residue and does not damage electronic equipment. Each hall is protected as an independent zone; discharge is triggered with dual detection confirmation, eliminating the risk of false discharge.

Detection
VESDA aspirating
Suppression
Novec 1230 gas
Triggering
Dual detection confirmation
Zoning
Independent per hall
Partitions
120 min fire resistance
Cabling
LSZH halogen-free
  1. STEP 1

    Early detection

    VESDA detects particles in the invisible stage.

  2. STEP 2

    NOC response

    The team finds the source on site; most incidents end here.

  3. STEP 3

    Dual confirmation

    Two independent detectors confirm the event and an evacuation warning is given.

  4. STEP 4

    Gas suppression

    Novec 1230 discharges only in the affected zone, within seconds.

06 — PHYSICAL SECURITY

7 layers · 24/7

7 layers from the perimeter fence to the rack door

Reaching your servers requires passing through seven independent checkpoints. Each layer performs verification independent of the previous one; all passages are recorded and can be reported for audit.

Visitors are notified in advance, pass an identity check, and move within the facility escorted by authorized personnel. Colocation customers can access only their own racks or cage areas, with person-specific authorization.

Personnel
24/7 security officers
CCTV
24/7 recording · 90-day archive
Inlet
Card + biometric
Mantrap
Single-person passage
Cabinet
Locked · person-specific
Logging
All passages are logged
123456 7 · RACK your server
  1. 01Perimeter security · fence, vehicle barrier, lighting
  2. 02CCTV · indoor and outdoor, 24/7 recording
  3. 03Security staff · reception and identity check
  4. 04Card access · zone-based authorization
  5. 05Biometric verification · white space entry
  6. 06Mantrap · controlled single-person passage
  7. 07Rack lock · person-specific, logged access

07 — NETWORK & CONNECTIVITY

Carrier-neutral

Carrier-neutral, multi-path backbone

The facility is operator-independent (carrier-neutral). Fiber lines enter the building by two physically separated routes and converge in the Meet-Me-Room (MMR); there you can connect directly to the carriers in the facility via cross-connect, or bring in your own carrier's line.

The NuageDC backbone runs in a BGP multi-homed design with multiple upstream providers at 4×100G capacity. Redundant core routers and in-line DDoS protection filter out attack traffic while traffic keeps flowing without interruption.

Explore Network & Connectivity services
Model
Carrier-neutral
Fiber entry
2 · separate routes
Backbone
4×100G
Routing
BGP multi-homed
Port
1 / 10 / 40 / 100G
DDoS
L3 / L4 / L7 protection
CONNECTIVITY TOPOLOGYSCROLL →
CARRIER ACARRIER BCARRIER C MEET-MEROOM CORE-R1CORE-R2 DDoSPROTECTION CUSTOMERRACK FIBER AFIBER B2×100G2×100GBGP

08 — NETWORK OPERATIONS CENTER

24/7/365 on site

The eyes and hands of the facility, on the floor at all times

Our NOC team works on site in shifts 365 days a year, 24 hours a day. Power, cooling, fire and security systems are followed through the building management system (BMS); rack power consumption, temperature and network traffic are tracked in real time through our DCIM and monitoring platforms.

Incident management follows defined processes: alarm, classification, response, customer notification and root cause analysis. With the Remote hands service, physical tasks such as server restarts, cable and disk replacement are carried out without you having to come to the facility.

Operation
24/7/365 on site
Monitoring
BMS · DCIM · SNMP
First response
< 15 min
Remote hands
Basic operations included
Reporting
Monthly SLA report

MONITORED POINTS

2.000+

Sensor, switchboard and device metrics

FIRST RESPONSE

< 15 min

On-site team for critical alarms

REPORTING

Monthly

SLA, incident and capacity reports

09 — RACK INFRASTRUCTURE

5 – 20 kW / rack

From a single server to a private cage, flexible rack options

42U and 47U standard racks are delivered with metered smart PDUs fed from the A and B lines. Power starts at 5 kW per rack in standard rows and goes up to 20 kW in high-density areas for GPU and dense virtualization workloads.

Structured fiber and copper cabling is neatly distributed through overhead cable trays. From 1U of space for a single server up to private cages with their own access control, you can choose the model that fits your needs.

Cabinet
42U / 47U · 600/800 mm
Power density
5 – 20 kW / rack
PDU
Smart, metered A+B
Capacity
120+ racks (Phase 1)
Cabling
Structured fiber & copper
SWITCHSWITCHSERVERSERVERSERVERSTORAGESTORAGEPATCHPATCH AB

RENTAL OPTIONS

  • 1U – 4USingle-server hosting
  • ¼ and ½ rackShared rack with locked compartments
  • Full rack42U / 47U, dedicated to you
  • Cage & private spaceWith your own access control

TECHNICAL SPECIFICATION

TRABZON-DC1 facility features

The facility's key technical values in a single table for your procurement and audit processes. Detailed project documentation is shared under a non-disclosure agreement.

Download as PDF
1/2 · BUILDING · POWER · COOLING
Trabzon Data Center technical specification: building, power and cooling
Building & space
LocationTrabzon Teknokent, Ortahisar · 40.9893° N 39.7705° E
Design standardTier III design principles · referencing TIA-942 / EN 50600
White space1,200 m² (Phase 1) + expansion area (Hall B)
Cabinet capacity120+ cabinets · 42U / 47U
FlooringRaised floor · high load capacity
Power
Grid supply2 × medium-voltage lines · separate substations
Total IT power1.2 MW (Phase 1)
UPS2N modular online UPS · ≥ 10 min autonomy
GeneratorN+1 diesel · < 15 s start-up · ≥ 72 h fuel
Rack feedA+B smart metered PDU · 5–20 kW / rack
Cooling
SystemN+1 CRAH + in-row units
Air managementCold aisle containment
Operating range22–24 °C · 40–60% RH (ASHRAE A1)
EfficiencyFree cooling · annual PUE target 1.37
2/2 · FIRE · SECURITY · NETWORK
Trabzon Data Center technical specification: fire, security, network and operations
Fire
DetectionVESDA aspirating early detection
SuppressionNovec 1230 gas · per-hall zone
Passive protection120 min fire-rated partitions · LSZH cabling
Security
Access control7 layers · card + biometric · mantrap
Monitoring24/7 CCTV · 90-day recording archive
Personnel24/7 security officers
Network
ModelCarrier-neutral · Meet-Me-Room
Backbone4×100G · BGP multi-homed
Fiber entry2 separate routes
ProtectionL3 / L4 / L7 DDoS protection
Operations
NOC24/7/365 on-site team · BMS / DCIM monitoring
Response< 15 min first response · remote hands
Service level99.99% infrastructure availability · monthly SLA report

SUSTAINABILITY

More computing power with less energy

An efficient data center is good for both the planet and your budget. Every system in the facility was selected to do the same work with less energy, and is operated with measurement.

Free cooling made possible by the Black Sea climate, aisle containment and high-efficiency UPS systems keep the PUE low. In the medium term, the aim is to meet the facility's consumption from renewable sources and to document this with certificates.

ANNUAL PUE TARGET

1.37

Ratio of total facility energy to IT load.

FREE COOLING

~%60

The share of the year that can be cooled with outside air.

UPS EFFICIENCY

%96+

Modular, high-efficiency double conversion.

LIGHTING

%100

LED and smart lighting with motion sensors.

Renewable energy target: to gradually meet the facility's consumption with renewable-source-certified (YEK-G) energy and to provide customers with per-rack energy and carbon reports.

CERTIFICATIONS & STANDARDS

Designed and operated to international standards

The standards we reference in facility design and the certifications we are targeting for our management systems. You can request current documents for your audit processes.

  • TIER

    Tier III

    Design principles

    Reference
  • TIA

    TIA-942

    Data center infrastructure

    Reference
  • ISO

    ISO 27001

    Information security

    Targeted
  • ISO

    ISO 22301

    Business continuity

    Targeted
  • ISO

    ISO 9001

    Quality management

    Targeted
  • ISO

    ISO 50001

    Energy management

    Targeted

"Reference": the standard used as the basis for design · "Targeted": a management system for which a certification process is planned.

OPERATIONS & MAINTENANCE

A redundant system is only as reliable as it is tested

Our preventive maintenance calendar checks every critical component before a failure occurs. Thanks to the redundant architecture, maintenance is carried out without interrupting your service.

  1. Daily

    • Shift handover and facility walk-through
    • BMS alarm and trend check
    • Hot spot and rack temperature check
  2. Weekly

    • No-load generator run
    • Fuel level and quality check
    • Review of security logs
  3. Monthly

    • Generator load test
    • UPS battery and module test
    • SLA and capacity report to customers
  4. Quarterly

    • CRAH filter and fan maintenance
    • Switchboard thermal camera scan
    • Review of access authorizations
  5. Semi-annual

    • Fire detection and suppression system test
    • VESDA calibration
    • ATS / STS transfer tests
  6. Yearly

    • Full-capacity test with load bank
    • Disaster scenario drill
    • Independent audit and risk assessment

Change management

Planned maintenance is announced at least 7 days in advance; every change goes through a risk analysis, a rollback plan and an approval process.

Incident management

Alarms are prioritized and affected customers are informed immediately; every incident is closed with a root cause analysis.

Capacity planning

Power, cooling and space usage are monitored continuously; your growth needs are planned ahead in the expansion area.

DISCOVERY TOUR

See our facility in person

Tour the facility accompanied by our engineers, from the power room to the white space and from the NOC to the Meet-Me-Room; ask all your questions on site before moving your infrastructure.

  • On a date that suits youAfter your request, the tour is scheduled within one business day at the latest.
  • Accompanied by an engineerOur power, cooling and network teams answer your questions.
  • Technical documentationAfter the tour, the specification and quote are shared under a non-disclosure agreement.

FREQUENTLY ASKED QUESTIONS

What people ask about the facility

The most frequently asked questions about the Trabzon Data Center's infrastructure, access rules and operations. For more, you can talk with our engineers during the discovery tour.

24/7 NOC Line

0212 951 00 61
Contact Us

The Trabzon Data Center is built on Tier III design principles, which aim at concurrent maintainability across the power, cooling and network layers, referencing TIA-942 and EN 50600. That means service continues without interruption while any component is taken out for maintenance. If you request them, we will share current documents on certification status.

Yes. Just submit your tour request; on a tour scheduled at least one business day in advance, you can walk through the power room, cooling infrastructure, white space and NOC accompanied by our engineers. An identity check and escort procedure apply during the visit; photography in the white space requires permission.

The moment the grid fails, the 2N modular UPS systems take over the load without interruption. The N+1 redundant generators start within 15 seconds and the load is transferred to the generators via the automatic transfer switchboards. The facility can run at full load on at least 72 hours of fuel reserve; our priority supply agreements secure refueling.

Standard racks start at 5 kW, and high-density areas provide up to 20 kW per rack. Each rack is fed from two independent lines, A and B, through metered smart PDUs; we report your consumption per rack.

Our facility is carrier-neutral. Through the Meet-Me-Room you can connect to the carriers already present in the facility via cross-connect, and you can also bring the line of the carrier you prefer. Fiber entries are made through two physically separated routes. For details, see the Network & Connectivity page.

Colocation customers can access the facility 24/7 with an authorized staff list. Every entry goes through card and biometric verification and a mantrap passage, and is recorded. For tasks that do not require you to come to the facility, you can use our remote hands service.

On request, our on-site NOC team performs physical tasks such as server restarts, cable checks and replacement, installing disks or modules, reporting LED and screen status, and receiving and mounting devices. Basic operations are included in the service; extensive jobs are charged hourly.

No. NuageDC's only data center is in Trabzon, and all our services run in this facility. Your data stays within the borders of Türkiye; the cross-border transfer obligations under KVKK do not arise.

GET A QUOTE

Let's talk about your project and prepare a quote tailored to you.

Briefly share your needs; our solution architects will review your current infrastructure and get back to you with a recommendation that balances performance, security and budget.

  • Reply within 2 business hoursDuring business hours your request is evaluated quickly.
  • Direct technical expertYou talk to a solution architect, not a sales rep.
  • Free migration planMigration steps are clarified together with the quote.

Fields marked with * are required.

Average response time: 2 business hours